The HP Smart Storage Manager (SSA) utility can only be launched during the Power-On Self-Test (POST) as a boot option. To start Smart Storage Manager, use the following instructions:

  1. Power-on or reboot the server. The Power-On Self-Test (POST) screen will be displayed.
    Power-On Self-Test (POST)
    Power-On Self-Test (POST)

    Note the message concerning the Embedded RAID Controller:

    Embedded RAID : Smart Array P440ar Controller - Configuration Required
    - 1785-Slot 0 Drive Array Not Configured Run HPSSA
  2. Press F10: Intelligent Provisioning. After several seconds the HP Intelligent Provisioning screen will be displayed.
    HP Smart Storage Administrator
    HP Smart Storage Administrator
  3. Select HP Smart Storage Administrator and press Enter. The HP Loading Screen will be displayed.
    HP Loading Screen
    HP Loading Screen

    After several seconds the HP Smart Storage Administrator screen will be displayed.

    HP Smart Storage Administrator
    HP Smart Storage Administrator
  4. From Available Device(s), select Smart Array P440ar. The Smart Array P440ar screen will be displayed.
    HP Smart Storage Administrator: Smart Array P440ar
    Smart Array P440ar
  5. Click Configure. The Smart Storage Administrator Configuration screen will be displayed.